英文摘要 |
In order to improve the problem of energy recovery seen in traditionalair-conditioners and heat pump heaters, a new type of multi-functionair-conditioner and heat pump heater was developed in this study. Withthe advantages of the traditional air-conditioning system and the heat pumpheater system, as well as a cooling source and thermal energy recycle andstorage, reduced energy usage was achieved. The system is designed withshared components of the traditional air-conditioner and heat pump heater.Additionally, in accordance with the CNS14464 and CNS15466 testmethods, the air-conditioner and directly heated heat pump performancewere confirmed in the laboratory (TAF1807). At the fixed capacity settingof 7.0 kW, the coefficient of performance of COPr 3.95, and thecoefficient of performance of COP 3.89 were obtained for the air-conditionerand heater respectively. Further, under the setting of the multifunctionair-conditioner and heat pump, the overall coefficient of performance ofCOPo 5.72 was achieved. |