Steam generators show the most severe condition of the corrosion in PWR secondary side because there are crevices between the tube bundles and support tube sheet, it may cause crevice corrosion in the intermediate gap. The accumulated sludge in the gap will gradually harden, it will press the tubes to cause denting. Maanshan Nuclear Power Plant utilizes hydrazine and ethanolamine to control water quality. The pH value in steam generator blow down is around 9.6 at 25℃. The concentration of hydrazine and ethanolamine are 30 ppb and 1 ppb respectively. Other impurity concentrations are quite low to near detection limit. Therefore, the designation of the experiment will test Inconel 600 alloy and Inconel 690 alloy in simulated PWR secondary side water chemistry circuit through different sample conditions and different water chemistry conditions. |