英文摘要 |
A high perfermance Liquid chromatographic method was described for determination of aloin in drinks at this report. Aloin was extracted and cleaned up through disposable cartridage (Adsorbex RP-18) using methanol-water (55 /45,V /V) as eluent. The eluted aloin was separated and detected by HPLC on Licrosorb RP-8 column with methanol-water (40 I 60,V / V) mobile phase,and measured at 295nm. The Limit detection level of aloin by this method was 0.04 ppm. When aloin added to sport drinks and soft drinks at the levels of 0.05-0.02μg/ml, the recovery were 86.81-97.92% from the former and 110.73-116.70% from the latter. the survey of aloin by this HPLC method resulted that aloin contents were not violated the regulation in 50 marketed drinks which collected from supermarkets in Taipei from Nov. 1988 to May 1989. The legal allowance amount for aloin in drinks was set at 0.1 mg / kg by the Health Department. |