英文摘要 |
This project conducted the insulation performance test of the general-purpose shoes to understandthe risk of electric shock when the wearers touch the voltage of 110 or 220V.The result of the low-voltage insulation test of 600V is: all of the leakage current less than thereaction threshold(0.5mA) and the let-go threshold(5mA) of human body, also less than the insulatinglimit value(1mA) of the low voltage lines.The shoes that soles made from rubber or PU material are capable of the insulation of 110 or220V, but those may be damaged due to nicks, cuts, abrasions or chemical contamination, so that theregular inspections and the visual inspections before use are necessary. Additionally, we should not usethat worn and damaged soles. |