| 英文摘要 |
The exhaust gas recuperator of the heating furnace of a factory was maintained annually in January 2019. It was found that both the hot air tube and the cold air tube of the recuperator were fractured and the cold air tubes were seriously damaged at the intersection of the end plate and the pipe joint. In order to understand the failure causes of the recuperator and to improve its service life , some analysis study was conducted. For speculating the failure cause, investigations and studies were performed. They were appearance examination, material composition analysis , hardness test, electrolytic etching in oxalic acid solution, metallography analysis, surface SEM/EDS analysis and corrosion products analysis etc.. According to the analysis results, it was speculated that the main failure cause for the breakage of the hot air tube was that the content of C in the material was higher and the amount of Ti was insufficient, this would result in material sensitization at high temperature, which combination with the precipitation of grain boundary carbides due to local carburization and the intrusion of S element from outside. They altogether caused intergranular corrosion of the hot air tube and leaded to fracture eventually. The main failure cause of the fractured cold air tube was caused by the abnormality of the original material; the main cause of corrosion of the cold air tubes at the junction of the end plate was caused by sulfuric acid dew point corrosion. Some suggestions for improvement and extending the service life of the equipment and to avoid similar situations were proposed. |