| 英文摘要 |
A waste heat recovery unit of petrochemical plant was utilized to heat up the heat transfer oil by hot flue gas. A significant wall thinning of the heat exchanger tubes was observed even though there is no obvious corrosion caused by heat transfer oil and flue gas. To comprehend the thinning causes of the tubes, the investigation works including collection of background information, visual inspection, microscopic analysis, X-ray diffraction and hardness measurement was performed. The analysis results revealed the heat transfer oil was thermally decomposed and changed into coke deposits on the internal surface of the heat exchange tubes. As a large amount of the coking particles formed and deposited on interior surface of tubes, the flowability of heat transfer oil was greatly diminished and the heat transfer efficiency was consequently deteriorated. The heat transfer oil would be ignited if tube temperature exceeded its ignition temperature. As a result, an overheating and even partial melting and wall thinning of tube material might occur. In addition, the countless tiny particles of coking substance and graphite would flow with vaporized heat transfer oil at high velocity and led to erosion and wall thinning at turbulent flow locations. |