| 英文摘要 |
The objective of this research is to study the failure reasons and preventive methods for debutanizer overhead air cooler in refinery. The possible corrosion mechanism in overhead system includes hydrogen chloride acid corrosion, salt deposit corrosion, wet hydrogen sulfide cracking and erosion-corrosion. Overhead system failure is very dependent on feed sources. In this study, acid corrosion is the main reason for this case and the source of acid corrosion comes from organic acids. The amount of acetic acid in feed was too high and reduced the pH value (pH ~ 4.0) of the overhead system. Neutralizing amine was added to control pH value. Corrosion inhibitor was applied to provide tube protection. However, inhibitor caused the following problems, most corrosion inhibitor polymerized to form black gel and caused heat exchanger to block up. The black localized gel could not provide good protection for tube but induced localized corrosion. After further studying, we find the main reason is neglecting the solubility of the corrosion inhibitor. Process stream is very light hydrocarbon in this case. If the solubility of inhibitor could not compatible with light process stream, inhibitor would loss its performance and caused negative effect for the system. The effective solutions are to choose suitable corrosion inhibitor and to control the pH value of the system by adding neutralizing amine. If water wash of overhead system is applied, the corrosion rate will be effectively reduced and controlled. |