| 英文摘要 |
It is the key unit in refinery to convert heavy oil into more valuable lighter products. Equipments in this unit are in the crucible of corrosive agents like hydrogen sulfide, chloride and cyanide. However, low pH value corrosion was the main cause for the performance failure in this case. In the period of emergency shutdown, the formation of excess sulfuric acid includes the decreasing of pH value of overhead system. When acids are involved, the effect of flow velocity on erosion-corrosion problem is often pronounced and extensive. Several strategies, including suitable surface treatment to protect the baffle, using water wash to cancel the concentration of corrosive agents and injecting enough neutralizer to control pH value in the range of 7.5~8.0 of overhead system, are suggested to minimize the corrosion problem. |