| 英文摘要 |
The current output of a full-wave (or half-wave) rectifier goes to zero 120 (or 60) times every second. Thereby, the standard rectifier itself acts as a fast interruption circuit. The waveform analysis method is based on this phenomenon. AD/DA card and microprocessor of comupter were used to read potential waveform data and a computer software was used to analyze waveform data. The pipe-to-soil potential and the polarization potential can be fastly obtained by above package. |