英文摘要 |
In 2014, the infection rate of CAUTI was (6.13 per mille), the major reason was found the low accuracy in implementation of foley bundle care、insertion technique of foley catheter is incorrect、knowledge deficit、lack of CAUTI education and training. After the integration of reference and team members discussion, Build up the bundle care of CAUTI were to replace the antiseptic from 10% betadine to 2% CHG during foley insertion, using checklist on foley insertion and care, education training, early catheter removal assessment and applied bedside electronic dashboard. The results show the rate of the CAUTI was decreased from (6.13 per mille) to (2.95 per mille). achieving the target(3.6 per mille). therefore, applying the bundle care of CAUTI, could reduce the foley catheter infection and improving the quality of medical care. |