市售電子血壓計之品質調查報告藥物
|
並列篇名 |
INVESTIGATION ON THE QUALITY OF MARKETED ELECTRONIC SPHYGMOMANOMETER IN TAIWAN AREA |
作者 |
鍾明翰、黃成禹、孫慈悌 |
中文摘要 |
本報告係針對市售之自量式電子血壓計做全面性之品質調查,于民國77年5月6日間,從台灣北部及南部各地區所抽購之檢體101件,按照衛生署自量式電子血壓計標準規格,就壓力換能器/標示器之精確度,以及電氣安全等兩項目進行測試,所得之結果顯示有百分之十三的產品不符合規定而其中國產品與輸入品之品質無質無顯著差別。 |
英文摘要 |
In order to understand the overall quality of electronic Sphygmomanometer currently on the market, a survey was conducted in Taiwan during May-June of 1988. A total of 101 randomly purchased samples from different area of Taiwan were analyzed. We conducted two measurements on the following parameters: Pressure Transducer I Indicator Accuracy and Electrical Safety. The results indicate that about 13%of the samples do not meet the reqquirements of the regulation standard. Further more, the survey shows that no significant difference was found on the average quality between the foreign and domestic products. |