英文摘要 |
In order to survey the quality of domestic and imported immunoglobulin injections used in market, 11 brands 47 lots 72 preparations of Human Normal Immunoglobulin Injection, 4 brands 5 lots 5 preparations of Human Antitetanus Immunoglobulin Injection, totaled 12 brands 52 lots 77 preparations were sampled from September 1985 to May 1986 in Taiwan area. The preparations were assayed to detect HBsAg by RIA and Anti-HIV by ELISA. The Anti-HIV positive lots were assayed further by Western Blot for Anti-HIV confirmation and by ELISA for HIV-Ag. The results showed that 52 lots (100%) are negative for HBsAg; 23 lots ( 44. 2%) strong positive , 1 lots (19.2%) postitive, 6 lots (11.6%) borderlined, 13 lots (25%) negative for Anti-HIV in 52 lots immunoglobulin injections . The 33 lots of Anti-HIV strong positive and positive injections are all positive by Western Blot for Anti-HIV and negative by ELISA for HIV-Ag. The results indicated that preparations of Human Normal and Antitetanus Immunoglobulin Injection produced from unscreened blood source for Anti-HIV by manufactories are contaminated with Anti-HIV but HIV-Ag is negative. |