英文摘要 |
PM10 have become air pollution index of urban air quality. It is also a dangerous pollutant for human health. PM10 in the urban areas would be mostly removed by air draft in the urban wind field. The wind field is subjected to urban block types, the building form etc. This study would judge how the building form affects the particle distribution. This study is based on observation and simulation. Urban block types in a school campus for an object wewe chosen in Taipei. Its distribution was measured and put into the database for the simulation of PM10 in different urban blocks types. Flovent5.1 would be applied for the comparison with three kinds of different types. The results demonstrate as following: First floor air draft plan reduces the PM10 concentration 67.5%, adds the wind speed 0.04m/s and affects surrounding environment up to 10 meters by distance. Building structure concentrated plan reduces the PM10 concentration 16.7%. Bridge connected buildings structure plan reduces the PM10 concentration 17.2%. |