英文摘要 |
Background & Problems: Hemodynamic monitoring is an important part of nursing care in the intensive care unit. Recent advances in medical technology and the diversification of intensive care equipment have increased the variety of instruments used in clinical hemodynamic monitoring. Many nurses who use new hemodynamic monitors are not familiar with instrument care, resulting in patient safety incidents caused by nurses not identifying warnings of hemodynamic data change and notifying doctors to provide treatment. The accuracy of hemodynamic monitoring care in our ward of 74.0% motivated this improvement project. Purpose: To improve the accuracy of hemodynamic monitoring care to 98.3%. Resolution: Conduct educational training and plan professional education; establish an audit system to regularly monitor the accuracy of nursing care; provide tips to make the operation manual easier to read and understand; establish mobile learning to make learning immediate and more accessible; hold instrument operation practice sessions to improve nursing staff proficiency; monitor and upload data to the hospital information system. Result: After the improvement project, the accuracy of hemodynamic monitoring care increased to 98.7%. Conclusions: The impact achieved met expectations, and the improvement project will be extended to other intensive care units in the hospital. Our nurses are now more familiar with the operation methods and the significance of monitoring values and interpretation of data. Also, when a value changes or becomes abnormal, they immediately notify the doctor for further evaluation and interventions to improve patient safety. |