This work evaluated the bioaerosol removal efficiency of three bioaerosol removal technologies, including neutral electrolyzed water spraying, carbon nanotube plasma, grapheme negative air ions in an indoor environment-simulated chamber. E. coli bioaerosol was chosen as the challenging bioaerosol. Bioaerosols were generated using a Collison three-jet nebulizer and sampling by BioStage impactor. The air exchanged rate and relative humidity of the chamber was set at 1.0 (1/hr) and 30%. The natural decay coefficient under ACH 0 and 1.0 (1/hr) was 0.028 and 0.187 (1/min). The removal coefficient under ACH 1.0 (1/hr)was 0.501 (min-1) for E. coli of FAC 50 ppm neutral electrolyzed water spraying; the removal coefficient under ACH 1.0 (1/hr) was 0.283 (min-1) for E. coli against 6 kV carbon nanotube plasma; the removal coefficient was 0.217 (min-1) for E. coli against grapheme negative air ions was. When these three removal technologies were working, the bioaerosol concentration would decrease to CFU/m^3 within 20 to 40 minutes. These finding indicated that three bioaerosol removal technologies have effective bioaerosol removal capability. |