以液相層析法及電位測量法檢測Clopidogrel   全文下載 全文下載
並列篇名
Liquid Chromatographic and Potentiometric Methods for Determinations of Clopidogrel
作者 AMR LOTFY SABER (AMR LOTFY SABER)MOHMED ALAA ELMOSALLAMY (MOHMED ALAA ELMOSALLAMY)ALAA ALSIDE AMIN (ALAA ALSIDE AMIN)HAMADA MOHMED AHMED KILLA (HAMADA MOHMED AHMED KILLA)
中文摘要
本研究中,兩種不同的技術被開發,並用於藥品製備中clopidogrel 之檢測。HPLC 法之分析條件為:Nova-PakR C18 管柱(3.9 mm × 150 mm,5 μm)、以甲酸調整至pH = 4 之甲酸胺緩衝溶液/ 乙?(40:60,v/v)為移動相、檢測波長為225 nm。結果呈現良好的線性(r = 0.9993)、準確度( ? 99.20%), 以及精確度( ? 0.6 RSD)。電位測量是根據tetrakis (p-chlorophenyl) borate-clopidogrel 離子對作為電流驅動物質,將塑化的PVC膜與o-nitrophenyl octyl ether 或dioctyl phthalate 混合。使用前,感應器需於0.1 M 藥品溶液中調整至少2 天。結果顯示,clopidogrel 在濃度範圍1.0 × 10-5 ~ 1.0 × 10-2 M,pH 範圍1.5 ~ 4.0 時,呈現快速又穩定之Nernstian 反應。平均回收率為100.6%,平均標準偏差為0.86%。在許多陰離子的存在下,感應器對於clopidogrel hydrogen sulphate 顯示出不錯的選擇性。賦型劑和稀釋劑之間無顯著差異。
英文摘要
Two different techniques are developed for the determination of clopidogrel in pharmaceutical preparations. HPLC method has been developed where chromatographic analysis is performed on Nova-Pak® C18 column (3.9 mm × 150 mm, 5 μm) with an ammonium formate buffer adjusted with formic acid to pH 4.0, acetonitrile (40:60, v/v) as mobile phase, and detection at 225 nm. Good linearity (0.9993, r), accuracy (≥ 99.20 %), and precision (≤ 0.6 RSD) were obtained. Potentiometric measurments are based on tetrakis (p-chlorophenyl) borate-clopidogrel ion-pair as an electroactive material incorporating a plasticized PVC membrane with o-nitrophenyl octyl ether or dioctyl phthalate. The sensor is conditioned for at least two days in 0.1 M drug solution before use. It exhibits fast and stable Nernstian response for clopidogrel over the concentration range of 1.0 × 10-5 ~ 1.0 × 10-2 M and pH range of 1.5 - 4.0. Results with an average recovery of 100.6% and a mean standard deviation of 0.86% of the nominal were obtained. The sensor shows reasonable selectivity towards clopidogrel hydrogen sulphate in presence of many cations. No significant interferences are caused by drug excipients and diluents.
起訖頁 11-18
關鍵詞 HPLC電位測定法藥物分析clopidogrel 檢測HPLCpotentiometrypharmaceutical analysisclopidogrel determination