英文摘要 |
This project was designed to implement the teaching and environmental achievements on the safety and hygiene developments. Besides the improvements on the experimental equipments by using capital expenses, this project also trained a group of students who processed working environment monitoring experience and then become the safety and hygiene assessing root personnels. 15 students laboratories was randomly choosed to study the indoor air quality (IAQ). Measured parameters include the concentrations of O2, CO, CO2, H2S, lower explosive level (LEL), indoor temperature, relative humidity, environmetal illuminace, and air speed of hood. The result on monitoring the experimental environment showed that 46.6% of the environmental illuminace was below the standard, 46.6% of the environmental failed to follow the CO standard and 60.0% of the environments failed to the H2S standard. As far as the illumination was concerned, the result showed that the environments did not select suitable light source and adequate light set locations. Indoor space scene and interior setups can determine the illumination status. Thus, regularly monitor local illuminance and change bad light sets are recommended. As far as the high CO and H2S concentration are concerned, it is obvious that the environment space was not big enough and general displacement of the indoor air and outdoor air, and local exhaust system are recommended. For laboratories that was equipped with air conditioning system, CO and H2S concentration should be monitored at least every six months in order to prevent damage to human health. |