英文摘要 |
In the ten working items of medical quality and patient safety, the critical values appearing in the report of pathogenic examination shall be reported and treated. In this case hospital, we developed a text-mediating platform for reporting critical values in 2009, and amplified to contain confirming function when physician receives the report mentioning critical values in the medical information system on June 2011. After this improvement, the average reply rate from physician when receiving critical value report was 43% between October 2011 and June 2012. We tried to use health failure mode and effect analysis (HFMEA) to find out the failure mode, effects, severity and occurring possibility in the physician reply system. Then, decision tree was used to make judgement and following with failure mode and effect analysis. The improvement plan was made after going through this procedure to find out the basic problem of failure replying. The result indicated 11 points of missing causing the failure. After discussion between every related faculty and referring to other hospital, an improvement procedure was made. The improved procedure was launched since August 2013, the successful reply rate within 24 h reached 98.6% after 3 months of operation. This study confirms that using HFMEA will positively improve the medical care quality. |