月旦知識庫
月旦知識庫 會員登入元照網路書店月旦品評家
 
 
  1. 熱門:
首頁 臺灣期刊   法律   公行政治   醫事相關   財經   社會學   教育   其他 大陸期刊   核心   重要期刊 DOI文章
JOURNAL OF FOOD AND DRUG ANALYSIS 本站僅提供期刊文獻檢索。
  【月旦知識庫】是否收錄該篇全文,敬請【登入】查詢為準。
最新【購點活動】


篇名
Sensitive electrochemical sensor of levofloxacin using boron-doped diamond (BDD) electrode modified with Ti3C2TX (MXene) material   全文下載 全文下載
作者 Prastika Krisma Jiwanti (Prastika Krisma Jiwanti)Indah Harindy Putri (Indah Harindy Putri)Grandprix T.M. Kadja (Grandprix T.M. Kadja)Yasuaki Einaga (Yasuaki Einaga)Laurencia Gabrielle Sutanto (Laurencia Gabrielle Sutanto)Siti Wafiroh (Siti Wafiroh)Dewi Kartika Azizah Sukardi (Dewi Kartika Azizah Sukardi)Anis Puspita Sari (Anis Puspita Sari)Tahta Amrillah (Tahta Amrillah)Ilma Amalina (Ilma Amalina)Qonita Kurnia Anjani (Qonita Kurnia Anjani)Wan Jeffrey Basirun (Wan Jeffrey Basirun)
英文摘要
Overuse of levofloxacin (LEV) is often associated with bacterial resistance and serious health problems, underscoring the need for reliable sensing and monitoring of LEV molecules. Therefore, this study aimed to investigate LEV using boron-doped diamond (BDD) and boron-doped diamond modified with MXene (Ti3C2TX) (BDD-MXene) electrode. The successful deposition of MXene on the BDD surface was confirmed using scanning electron microscope (SEM). Cyclic voltammetry (CV) and square wave voltammetry (SWV) methods were also applied to evaluate the electrochemical behavior. The results showed that both electrodes had a linear response in the range of 30e100 mM. The limit of detection (LOD) and limit of quantitation (LOQ) were found to be 1.0£10¡6 M and 3.37£10¡6 M for bare-BDD, while on BDD-MXene, the values were 3.90£10¡7 M and 1.30£10¡6 M, respectively. Furthermore, both electrodes showed good responses on selectivity tests with glucose and another fluoroquinolone antibiotic such as ciprofloxacin. The results also indicated good precision with %RSD less than 5%. In real sample applications using wastewater, bare-BDD and BDD-MXene produced excellent %recovery of 92.96% and 101.29%, respectively.
起訖頁 348-357
刊名 JOURNAL OF FOOD AND DRUG ANALYSIS  
期數 202409 (32:3期)
出版單位 衛生福利部食品藥物管理署
該期刊-上一篇 Production and characterization of encapsulated Thymoquinone loaded bacterial cellulose/chitosan composite nano film and investigation of its in vitro antibacterial activity
該期刊-下一篇 Optimization, physicochemical stability and in vivo study of alginate-chitosan composites as nanocarriers for low molecular weight angiotensin I-converting enzyme (ACE)-inhibitory peptide
 

新書閱讀



最新影音


優惠活動




讀者服務專線:+886-2-23756688 傳真:+886-2-23318496
地址:臺北市館前路28 號 7 樓 客服信箱
Copyright © 元照出版 All rights reserved. 版權所有,禁止轉貼節錄