月旦知識庫
 
  1. 熱門:
 
首頁 臺灣期刊   法律   公行政治   醫事相關   財經   社會學   教育   其他 大陸期刊   核心   重要期刊 DOI文章
JOURNAL OF FOOD AND DRUG ANALYSIS 本站僅提供期刊文獻檢索。
  【月旦知識庫】是否收錄該篇全文,敬請【登入】查詢為準。
最新【購點活動】


篇名
Three-Way Analysis-Based pH-UV-Vis Spectroscopy for Quantifying Allura Red in An Energy Drink and Determining Colorant's pKa   全文下載 全文下載
並列篇名
Three-Way Analysis-Based pH-UV-Vis Spectroscopy for Quantifying Allura Red in An Energy Drink and Determining Colorant's pKa
作者 Erdal Dinç (Erdal Dinç)Nazangül Ünal (Nazangül Ünal)Zehra Ceren Ertekin (Zehra Ceren Ertekin)
英文摘要
Three-way analysis-based pH-UV-Vis spectroscopy was proposed for quantifying allura red in an energy drink product without the need for chromatographic analysis, and determining the colorant's pKa without using any titration technique. In this study, UV-Vis spectroscopic data matrices were obtained from absorbance measurements at five different pH levels from pH 8 to pH 12 and arranged as a three-way array (wavelength x sample x pH). In the three-way analysis procedure, parallel factor analysis (PARAFAC) was implemented to decompose the three-way array into a set of trilinear components. Each set of three components relates to spectral, pH and relative concentration profiles of allura red and sample matrix in the energy drink. First, UV-Vis spectra of the colorant's acid-base pair and sample's matrix were characterized by using the estimated spectral profile. Then, from the pH profile the pKa value was found to be 11.28 for the related colorant. Finally, allura red in energy drink samples was determined using the estimated concentration curve in the relative concentration profile. In the quantitation procedure, the working concentration range was 0.8-19.2 mg/mL. PARAFAC approach was tested in terms of selectivity, precision, and accuracy of the method. Added recovery results obtained by applying the proposed method to spiked samples were between 101.5% and 103.5%. In the application of the method to the analysis of real samples, successful results were reported. For a comparison, an ultra-performance liquid chromatographic method was developed for the quantitation of the colorant. Compared to the chromatographic method, we observed that PARAFAC model was simple and less expensive without requiring separation.
起訖頁 76-86
關鍵詞 Allura red AC dyeEnergy drinkspKa estimationQuantitationThree-way analysis
刊名 JOURNAL OF FOOD AND DRUG ANALYSIS  
期數 202103 (29:1期)
出版單位 衛生福利部食品藥物管理署
該期刊-上一篇 Effects of Beer Based Marinades on the Plasmalogen Content and Composition of Grilled Ruminant Meats
該期刊-下一篇 Non-digestive stachyose enhances bioavailability of isoflflavones for improving hyperlipidemia and hyperglycemia in mice fed with high fat diet
 

新書閱讀



最新影音


優惠活動




讀者服務專線:+886-2-23756688 傳真:+886-2-23318496
地址:臺北市館前路28 號 7 樓 客服信箱
Copyright © 元照出版 All rights reserved. 版權所有,禁止轉貼節錄