英文摘要 |
This study investigated the performance of brace connections in new reinforced concrete (RC) frame buildings with buckling-restrained braces (BRB) arranged in a zigzag configuration. A 12-story buckling-restrained braced RC building following model building codes is proposed as a prototype. To verify the constructability and seismic performance of the proposed connection, the beam-column joint at the tenth floor was selected as a sub-assemblage specimen, designed, and fabricated. The full-scale sub-assemblage, including the BRB gusset bracket and a pair of RC corbels, in the proposed BRB RC frame structural system was tested using a cyclic loading procedure. The test results demonstrate that the proposed BRB-to-RC connection performs well without failure in the steel gusset bracket or the RC corbels. The design and construction of the sub-assemblage specimen shows the feasibility of the proposed system for practical applications. |