英文摘要 |
The building of Taitung’s Fire Department shows some structural weaknesses because of its special configuration in the first storey. The 0401 earthquake caused serious damage on the said building. NCREE(National Center for Research on Earthquake Engineering) researchers visited the area to make a full exploration and sampling of concrete and steel to analyze the building’s structural strength. All the gathered data can serve as a reference for further works. Under the Taiwan Strong Motion Instrumentation Program, accelerographs had been installed in the Taitung Fire Bureau Building by the Central Weather Bureau. The strong motion records, damage records and material test data are considered as important references in the detail evaluation of the building. In this paper, the detailed damage records, concrete compression test and steel tensile strength test were carried out. Besides, the seismic motion records such as 921, 1022 and 0401 earthquakes were also introduced in the manuscript. |