The purpose of this project was to reduce unplanned re-catheterization intravenous injection. Factors associated with re-catheterization intravenous therapy were identified, including local swelling of an insert site and obstruction of a transporting tube. The major causes associated with local swelling of an insertion site were insufficient absorption of the fluid and medication leakage within the insertion site. The components associated with the obstruction of the transporting tube were due to displacement of a connector and inappropriate distance from the insertion site to the IV (intravenous) bottle. All these factors resulted in increasing nursing efforts and wasting the medical materials. Thus, a continuous nursing education in relation to intravenous injection was designed and applied. An IV caution card was hanged on the IV bottle. The results revealed a decrease in the re-catheterization rate from 22.5% to 5.8%. In addition, both nursing workload and expurgate medical material were reduced. The results of this study presented an improving of re-catheterization of intravenous injection, and improving quality of nursing. |